itel IPV-11K48T 11kW Hybrid Inverter
Price on request
Full specifications
| Brand | iTel |
| Inverter Specifications | |
| Model | IPV-11K48T |
| Inverter type | Hybrid |
| Grid type | Single Phase |
| IP class | IP54 |
| Warranty | 3 Years |
| PV Input Data | |
| Max DC input power | 16500 W |
| PV input voltage | 535 V |
| MPPT voltage range | 75-500 V |
| Max. PV input current | 30 A |
| No. of MPPT | 2 |
| No. of strings per MPPT | 2+1 |
| Startup voltage | 85 V |
| AC Output Data | |
| Rated AC output | 11000 W |
| Rated AC output current | 50 A |
| Rated voltage | 230 V |
| Smart load / generator input | Yes |
| Parallel operation | Yes |
| Battery Data | |
| Battery type | Lithium & Lead-Acid |
| Battery voltage range | 40-60 V |
| Max. charging current | 200 A |
| Max. discharging current | 220 A |
| BMS | WiFi / RS485 / CAN / Dry-contact |
| Protections | |
| AC overcurrent protection | Yes |
| Output short circuit protection | Yes |
| Surge protection | Yes |
| Over voltage protection | Yes |
| General Specifications | |
| Weight | 20 kg |
| Operating temperature | -25°C ~ +60°C |
| Size (W×H×D) | 410 × 600 × 156 mm |
Note: 11,000 W and 11,000 VA on a 48 V battery bank (40 to 60 V, lead-acid, lithium or user-defined) from up to 16,500 W of PV, 150% of the output, across two MPPTs that are not interchangeable: 30 A on one and 20 A on the other, with two strings on the first and one on the second, over a 75 to 500 V window with a 535 V ceiling and an 85 V start. The front page of the datasheet rounds the PV figure to 16 kW; the table gives 16,500 W. 200 A charging from solar, 180 A from mains or generator and 220 A discharge. Output is 220/230/240 V at 50/60 Hz with up to 50 A, and the AC input accepts 90 to 280 V and passes up to 73 A in bypass. Surge 18,000 VA for 5 seconds, with overload staged from 102 to 110% for 1 minute, 110 to 130% for 15 seconds, 130 to 150% for 10 seconds and above 150% for 5 seconds. Switchover is under 10 ms in UPS mode and under 20 ms for appliances. Certification is IEC 62109-1, IEC 62109-2 and IEC 61683 only, and the datasheet has no grid-output or feed-in section. The IEC 62116 anti-islanding and IEC 61727 grid-connection standards a net-metering application normally needs are not listed, so confirm with your installer before counting on net metering. The sheet publishes 99.9% MPPT tracking and 94% battery-mode conversion but no PV-to-AC efficiency, so the efficiency field is left empty rather than filled with a number that measures something else. Its harmonic distortion row reads 98%, which cannot be a distortion figure, so it is not used. Against the IPV-8K48T: the same 410 × 600 mm footprint, the same 30 A plus 20 A trackers, 535 V ceiling and 85 V start, but 3000 W more output, 500 W more PV, 200 A instead of 160 A solar charging and 220 A instead of 180 A discharge, for 1 kg more. Supports a diesel generator and a smart load, and parallels to 12 units in single or three phase. WiFi, RS485, CAN and dry contact. IP54, fan-cooled at under 60 dB, rated -25 to +60 °C with derating above 45 °C, up to 3000 m with derating above 2000 m. Protection covers overvoltage, overload, short circuit and over-temperature, with Type III surge protection on both the DC and AC side. 20 kg in a 410 × 156 × 600 mm case (length × width × height on the sheet). 3-year replacement. None of w11stop.com, Kamal Solar, alladin.pk, sunsolar.pk or smartsolar.pk listed this model when checked on 21 and 22 September 2026, so no price is shown yet.